Etched metal parts for medical and laboratory equipment
Medical and laboratory equipment uses a lot of thin stainless and titanium parts whose edges must be clean: filter meshes, screens, spacers, flat springs and marked plates. Etching produces them without burrs, without heat and without the loose fibres a woven mesh can shed, which is why it is the usual route for parts that will be cleaned, sterilised and reused.

Parts we etch for this sector
| Part | Why etching |
|---|---|
| Filter meshes and screens | One solid sheet, so no wires shift and no fibres are shed into the filtrate |
| Spacers, shims and washers | Burr-free from 0.05 mm, so stacks seat correctly |
| Flat springs and clips | Hard temper strip keeps its spring rate; etching applies no heat |
| Templates, guides and gauges | Fine features and edges that are safe to handle |
| Instrument dials, scales and marking plates | Graduations etched into the metal, so autoclaving does not remove them |
| Shields and housings for diagnostic electronics | Etched flat with fold lines, then formed |

Why an etched screen rather than a woven mesh
- Nothing to unravel. The screen is a single sheet, so no wire can shift or work loose.
- Exact openings. Hole size, shape and spacing are whatever the drawing says, including zones of different open area on one screen.
- Cleanable. A one-piece sheet can be back-flushed and ultrasonically cleaned without distorting.
- Smooth edges. No burr to trap residue or to damage a seal.
Materials and limits
- Materials: stainless steel 304, 316 and 316L, titanium, nickel alloys and copper alloys. 316L and titanium are the usual choice where corrosion resistance matters most.
- Thickness: 0.05 mm to 5.0 mm; meshes and screens are usually 0.05 mm to 0.3 mm.
- Minimum hole: about 1 to 1.2 times the sheet thickness, so thinner sheet gives finer filtration.
- Tolerance: Tolerance can be held to ±0.01 mm, depending on material thickness and part size.
- Finishing: passivation and electropolishing for a smooth, clean surface.
Where these parts are used
We are a Beijing etching works, established 2003. What we supply is etched metal components for medical, dental and laboratory equipment: filter screens, spacers and shims, flat springs, templates and gauges, instrument dials and marked plates. Tell us the grade, the finish and any documentation you need with the parts at the enquiry stage, and we will confirm what we can provide before you order.
Related: etched filters and screens, titanium etching, etched shims and passivation and electropolishing.
Request a quote
Send the drawing in DXF, DWG, STEP or PDF format with the material and grade, the thickness, the quantity and any documentation you need with the parts. We check the feature sizes against the drawing before tooling and tell you what to change if anything falls below the limits above. Sample lead time is typically 3 to 7 working days. Drawings are treated as confidential. Send yours through our contact page.
Medical and laboratory parts: FAQ
Can etched parts be passivated or electropolished?
Yes. Passivation restores the passive layer on stainless steel after etching, and electropolishing gives a smoother, brighter surface that is easier to clean. Both are usual for filter screens and for parts that are washed repeatedly. State the requirement on the drawing.
Why use an etched screen instead of a woven mesh?
An etched screen is one solid sheet, so no wires can shift or work loose and nothing is shed into the filtrate. Hole size, shape and spacing come from the drawing, and the sheet can be back-flushed and ultrasonically cleaned without distorting.
Which stainless grade should I specify for a medical part?
316 or 316L where corrosion resistance and repeated cleaning matter most, 304 for general equipment parts. Titanium is used where the lowest reactivity is wanted. Passivation and electropolishing can be added after etching.
How fine can an etched filter screen be?
The minimum hole is about 1 to 1.2 times the sheet thickness, so a 0.05 mm sheet carries holes of roughly 0.05 to 0.06 mm. Finer filtration needs thinner material.